Revolutionizing Effluent Treatment Efficiency

In Nagpur, a significant energy-saving transformation was achieved at an Effluent Treatment Plant with the expertise of Seetech Solutions Pvt. Ltd. The plant's pump, operating 16 hours daily and 365 days a year, previously utilized IE1/IE2 motors. These legacy motors, though functional, incurred substantial electricity costs, directly impacting profitability.

To address this, the pump-set was upgraded with Matel's cutting-edge ULTRAMATE™ Series IE5 Permanent Magnet Synchronous Motor. This high-efficiency motor significantly reduced power consumption while enhancing performance.



Before Implementation: The pump, powered by a 15KW IE1/IE2 motor running at 2940 RPM with a VFD, consumed 16.69KW of input power. It delivered a flow of 126.2m³/hr at an output pressure of 2Kg/cm².


After Implementation: The ULTRAMATE™ IE5 motor, operating at 13.37KW input power and 2750 RPM, increased the flow to 132.3m³/hr at the same output pressure of 2Kg/cm².



Key Results:

  • Energy savings of 19.89%, drastically cutting operational costs.

  • Enhanced pump performance with optimized flow rates and reduced power usage.

  • Demonstrated the efficiency and precision control of Matel’s synchronous motor technology.

This case study underscores how advanced motor technology can revolutionize industrial efficiency and sustainability, setting new benchmarks for energy savings and operational excellence.